Agriculture and Horticulture Galvanised Steel Storage Tanks
Tasman Tanks range of Agriculture tanks are designed to store volumes from 150kL to 6000kL, utilizing our proven cost effective design with out the need for pouring expensive concrete foundations. Our range of Agricultural tanks can be constructed on compacted gravel foundations, and erected quickly to provide storage capacities to meet your requirements.
These tanks are designed for use in areas such as;
Dairy Effluent
Horticulture
Irrigation
Livestock Effluent
Due to the low height and large diameter of these tanks, they do not support roof structures. To make allowance for rainwater a slight increase in tank storage capacity can be requested.
Tanks can be fitted with our standard attachment's and nozzles or special fittings as per our clients request.
Tasman Tank Range
Contact Tasman Tanks for more information on our Agriculture Tank Range. If you have an application which does not suite our Agriculture tank, Tasman has other tank designs that will be able to meet your requirements such as our TS600 Circular liner tanks which can be constructed complete with roofs and access requirements. Talk to one of our Tank Specialists about your specific requirements so we can offer you the right solution.
10 Year Liner Warranty
Standard Sizes from 72,000 litres (72m³) to 6 million litres (6000m³)
Heights Available
150m³ to 3000m³ - 2.1m wall height
1000m³ to 6000m³ - 2.7m wall height
For the Future of Our Environment
Tasman Tanks Standard Features
- Butterfly valve included for outlet
- Galvanised steel compression wind girder
- Galvanised steel wall panels and fasteners
- Engineers Producer Statement (PS1) supplied on each tank
- Stainless steel inlet and outlet supplied
- Mechanical ground Anchors
- Tasman's dedicated project Coordinators will provide free assistance with the preparation of the building consent if required
Auxiliary Items Available
PS4 available if required
Additional outlets/inlets
Rectangular side access man-ways can be fitted
Mechanical liquid level indicator
Vacuum tanker outlet
Fittings for installation of most proprietary stirring systems
Colour Options
Additional Powder Coating available in a range of standard powder coating colours.
Engineering Design Criteria
- Engineering Design to AS/NZS1170.0
- Design life (structural) - 50 years
- Design life (durability) - 25 years
- IL 1 Design Classification
- To Wind Speed - 45m/s
- Terrain Category 2
- Subsoil Class D
- Seismic Design - each tank is designed and certified to your specific Seismic Region
Anchoring
Ground anchors are standard on all tanks, ensuring reliability during high winds and seismic events.
Tank Foundations
The inherent resiliency of bolted steel construction avoids the need for concrete foundations.